CONFOCAL MICROSCOPE

Next Generation FLUOVIEW for the Next Revolutions in Science

The FLUOVIEW FV3000 series of confocal laser scanning microscopes meets some of the most difficult challenges in modern science. Featuring the high sensitivity and speed required for live cell imaging as well as deep tissue observation, the FV3000 confocal microscope enables a wide range of imaging modalities, including macro-to-micro imaging, super resolution microscopy, and quantitative data analysis. Choose between upright and inverted microscope frames suited for a range of life science applications, including developmental biology, stem cell research, electrophysiology, cancer research, slide imaging, and more.
Main Laser
405 nm: 50 mW, 488 nm: 20 mW, 561 nm: 20 mW, 640 nm: 40 mW |
One optional laser port for the sub laser combiner or optional laser unit
Optional Laser
445 nm: 75 mW, 514 nm: 40 mW, 594 nm: 20 mW |
Sub laser combiner Laser as follows (max. 3 laser units )
or direct connection to main combiner (single laser unit)
Scanner
FV3000 | FV3000RS |
---|---|
2 silver-coated galvanometer scanning mirrors | 2 silver-coated galvanometer scanning mirrors 1 silver-coated resonant and 1 silver-coated galvanometer scanning mirrors |
Scanning Method
Scanning Resolution: 64 × 64 to 4096 × 4096 pixels Scanning Speed (One Way): 512 × 512 with 1.1 s – 264 s. pixel time : 2 μs – 1000 μs Scanning Speed (Round Trip): 512 × 512 with 63 ms – 250 ms / 256 × 256 with 16 ms – 125 ms Optical Zoom: 1X – 50X in 0.01X increments Scan Rotation: Free rotation (360 degrees) in steps of 0.1 degree Scanning Mode: PT, XT, XZ, XY, XZT, XYT, XYZ, XYλ, XYZT, XYλT, XYλZ, XYλZT ROI scanning, rectangle clip, ellipse, polygon, free area, line, free line, and point ;tornado mode only for stimulation |
Galvanometer Scanner (Normal Imaging)
FV3000 | FV3000RS |
---|---|
Scanning Resolution: 512 × 32 to 512 × 512 pixels Scanning Speed: 30 fps at 512 x 512, 438 fps at 512 × 32 Optical Zoom: 1X – 8X in 0.01X increments Scanning Mode: XT, XZ, XY, XZT, XYT, XYZ, XYλ, XYZT, XYλT, XYZ, XYλZT ROI Scanning, Rectangle Clip, Line |
Resonant Scanner (High-Speed Imaging)
hIGH sENSITIVITY – SPECTRAL DETECTOR
Cooled GaAsP photomultiplier, 2 channels |
Motorized Volume Phase Holographic transmission diffraction grating, motorized adjustable slit selectable wavelength bandwidth: 1–100 nm, wavelength resolution: 2 nm |
Detector Module
SPECTRAL DETECTOR
Multi-Alkali photomultiplier, 2 channels |
Motorized Volume Phase Holographic transmission diffraction grating, motorized adjustable slit, selectable wavelength bandwidth: 1–100 nm, wavelength resolution: 2 nm |
Detector Module